We produce different classes of concrete in line with our diverse customer needs: 

Class Grade Mix Ratio (cement : sand : aggregates) COMPRESSIVE STRENGTH Recommended for:
MPa (N/mm2) psi
Class 15 1:3:6
15 MPa 2175 psi Suitable as blinding and/or levelling concrete
Class 20 1 : 2 : 4 20 MPa 2900 psi Used for general road drainage works and small-span residential building structures.
Class 25 1 : 1.5 : 3 25 MPa 3625 psi Generally recommended for most structural works or as specified by the design structural engineer.
Class 30 Design Mix 30 MPa 4350 psi Mostly used as structural concrete in high-rise buildings, especially on columns or as specified by the design structural engineer.
Class 35 Design Mix 35 MPa 5075 psi For projects as specified by the design structural engineer.
Class 40 Design Mix 40 MPa 5800 psi For projects as specified by the design structural engineer.

Besides these, we also make concrete mix designs for screed mix, shot create, and pavement concrete.